Drawings to send
- Architectural wall plans and elevations
- Masonry wall types and reinforcement details
- Lintel and opening schedules
Get masonry quantities by wall type and bond for a commercial bid. Review opening deductions by elevation and reconcile CMU, veneer, grout and lintels against the specified assemblies.

Send elevations, wall types, and the opening schedule, and state the opening-deduction rule you want used.
Masonry is typically $150–$1,000 per estimate. The amount tracks project size and scope, and 24–48 hours covers delivery for most estimates.
Each wall type is an area by length and height, minus openings under the rule you specify. A 48 by 12 foot wall is 576 SF gross. One 6 by 7 foot opening deducts 42 SF, leaving 534 SF net before bond and waste. CMU and brick veneer are not the same row. Grout is based on the specified cells, not on an assumed solid wall. Lintels, ties, and control joints are counted from the details. Scaffold and weather-barrier ownership are written exclusions.
These rows show how a commercial workbook can separate units. They are teaching lines, not a client bid and not a price.
| Line item | Unit or basis | Drawing reference | Review note |
|---|---|---|---|
| CMU wall area | SF | Wall type and elevation | Net of stated opening rule |
| Brick veneer | SF | Elevations | Separate from CMU backup |
| Grout and reinforcing | As specified | Wall sections | Only the cells or zones detailed |
| Lintels | EA | Opening schedule | Not included in wall SF |
Measure each wall type by elevation and thickness, using the stated opening-deduction rule. Separate CMU and veneer areas, grouted cells, reinforcement, lintels, ties and flashing; convert area into unit counts only with the specified module.
Check scaffold access, veneer support and weather-barrier ownership. Grout should follow specified cells or zones rather than an assumed solid-wall volume.
Illustrative wall: 48 ft long x 12 ft high = 576 SF gross. A 6 ft x 7 ft opening deducts 42 SF, leaving 534 SF net before bond pattern and other adjustments.
When the measurement rule you confirm says so. The deduction is shown, not absorbed silently.
Only with the specified module size. Area is not converted to block or brick counts without that module.
Relief angles and veneer support are included only when the structural and architectural sheets assign them to the mason. Otherwise they are flagged.
Inclusions, exclusions, and whether this trade is in your package are confirmed in the project quote. This page does not certify design or code compliance. PlanSwift and Bluebeam are named only as tools used in the industry.