Drawings to send
- Below-grade and wet-area details
- Membrane and protection specifications
- Foundation and drainage plans
Send waterproofing details for the assemblies in your bid. The workbook separates vertical and horizontal membranes, drainage and protection layers, and linear terminations for review.

Send below-grade and wet-area details and say whether excavation access and flood testing are in this package.
Below-grade and wet-area scope is typically $150–$1,000 per estimate. Most estimates are delivered in 24–48 hours, with the fee tied to project size and scope.
A foundation wall 75 feet long and 8 feet high is 600 SF gross before corners, laps, and penetrations. Horizontal deck membrane is a different assembly from the vertical wall. Protection board and drainage composite are their own areas when specified. Termination bars and joints are linear feet. Substrate repair is an allowance or an exclusion, not a hidden extra on the membrane SF. The workbook names the assembly so a plaza deck is not priced as a blindside wall.
These rows show how a commercial workbook can separate units. They are teaching lines, not a client bid and not a price.
| Line item | Unit or basis | Drawing reference | Review note |
|---|---|---|---|
| Below-grade wall membrane | SF | Foundation section | Gross face before laps |
| Horizontal deck membrane | SF | Deck details | Separate assembly |
| Protection board | SF | Specification | Not assumed equal to membrane |
| Terminations and joints | LF | Details | Penetrations counted |
Measure membrane extents by below-grade wall, horizontal deck or wet-area assembly. Record terminations, laps, joints, protection board and drainage layers separately.
Substrate repair, excavation access, transitions to roofing and flood testing require explicit ownership. Do not count only the flat membrane area and omit perimeter details.
Illustrative foundation wall: 75 ft x 8 ft = 600 SF gross treatment area before overlaps, corners, terminations and penetrations.
The 600 SF is gross wall face. Lap, corner, and penetration extras are additional rows when the specification measures them that way.
Roof membrane belongs on the roofing guide unless the detail is a waterproofed deck that the documents assign to this package.
Flood testing and warranties are responsibility lines. They are included only when the request says so.
Inclusions, exclusions, and whether this trade is in your package are confirmed in the project quote. This page does not certify design or code compliance. PlanSwift and Bluebeam are named only as tools used in the industry.