Drawings to send
- Civil utility plans and profiles
- Connection and structure schedules
- Utility material specifications
Send civil plans and profiles for a site utility takeoff. We separate storm, sanitary and water systems by pipe size, material and depth zone, and flag the connection to building plumbing.

Send civil utility plans, profiles, and structure schedules, and note which contractor owns pavement restoration.
Most estimates for underground utilities are delivered in 24–48 hours. Fees are typically $150–$1,000 per estimate, set by project size and scope.
Storm, sanitary, and water alignments are listed by material, diameter, and depth zone. A run of 120 LF of 6-inch pipe stays off a run of 45 LF of 8-inch pipe. Manholes, inlets, valves, and tie-ins are counted from the plan. Bedding, trench support, testing, and pavement patch are separate scope lines. Utility-company charges are exclusions unless you ask for them as allowances. The workbook uses one sheet per system so a storm structure is not priced as a sanitary manhole.
These rows show how a commercial workbook can separate units. They are teaching lines, not a client bid and not a price.
| Line item | Unit or basis | Drawing reference | Review note |
|---|---|---|---|
| Storm pipe by size | LF | Profile | Keep each diameter on its own row |
| Sanitary pipe by size | LF | Profile | Separate from storm |
| Water main and services | LF and EA | Civil water plan | Valves counted |
| Structures | EA | Structure schedule | Inlets are not manholes |
Measure storm, sanitary and water alignments by size, material and depth zone. Count structures, fittings, valves, tie-ins and service connections against plans and profiles.
Confirm trench support, bedding, restoration, testing and utility-company charges separately. Pipe centerline length alone does not define excavation volume.
Illustrative utility line: 120 LF of 6 in pipe plus 45 LF of 8 in pipe must remain separate size-based quantities; excavation and restoration are separate scope checks.
Fittings and valves are counted when the plan shows them. They are not assumed as a percentage of length.
The estimate names the party. Restoration SF is measured only where the civil sheets show the patch limits.
No. The five-foot line or the point of connection on the drawings is the handoff. Both sides are not measured in both packages.
Inclusions, exclusions, and whether this trade is in your package are confirmed in the project quote. This page does not certify design or code compliance. PlanSwift and Bluebeam are named only as tools used in the industry.