Drawings to send
- Envelope and partition assemblies
- Thermal and acoustic insulation schedules
- Mechanical insulation specifications
Commercial insulation is several scopes: thermal envelope, acoustic batts, duct wrap, and pipe insulation. They do not share one square-foot rate.

Send wall and roof assemblies plus the mechanical insulation specification, and name which of those you want measured.
Insulation quantities are typically quoted at $150–$1,000 per estimate, scaled to project size and scope, with most estimates delivered in 24–48 hours.
Envelope insulation follows the wall or roof assembly and its thickness. A 50 by 9 foot wall is 450 SF gross before any required opening deduction. Acoustic batts in partitions follow the wall tag, not the exterior wall. Duct and pipe insulation follow the mechanical runs and the specified facing. Roofing insulation stays with the roof assembly when that trade owns it. Firestopping is not insulation. The workbook uses a scope column so envelope, acoustic, and mechanical insulation cannot be filtered into one total by mistake.
These rows show how a commercial workbook can separate units. They are teaching lines, not a client bid and not a price.
| Line item | Unit or basis | Drawing reference | Review note |
|---|---|---|---|
| Exterior wall insulation | SF | Wall assembly | Thickness and facing |
| Roof insulation | SF | Roof assembly | Coordinate with the roofing package |
| Acoustic batt | SF | Partition type | Only on tagged walls |
| Duct or pipe insulation | SF or LF | MEP insulation spec | Separate from envelope SF |
Separate thermal envelope, acoustic partitions, duct and piping insulation. Record thickness, facing, location and measurement basis for each assembly.
Coordinate with roofing, drywall and MEP packages to avoid duplicate insulation. Firestopping and fireproofing are different scopes from ordinary thermal or acoustic insulation.
Illustrative wall insulation: 50 ft x 9 ft = 450 SF gross; deduct openings only when the scope and measurement rules require it.
Only when the assembly and the measurement rule require it. The rule is written on the row.
No. Sheet-metal surface and insulation surface can differ at fittings and where wrap is not specified.
No. Spray fireproofing and firestopping are different specifications from thermal or acoustic insulation.
Inclusions, exclusions, and whether this trade is in your package are confirmed in the project quote. This page does not certify design or code compliance. PlanSwift and Bluebeam are named only as tools used in the industry.